TOTAL FREE HEALTH AND SAFETY DOCUMENTS DOWNLOADING SOURCE

 


Breaking

Saturday, November 16, 2024

HSE DOCUMENTS-DRILLING RIG INSPECTION CHECKLIST

HSE DOCUMENTS-DRILLING RIG INSPECTION CHECKLIST
HSE DOCUMENTS-DRILLING RIG INSPECTION CHECKLIST

A "Drilling Rig Inspection Checklist" by HSE Documents ensures safety and operational efficiency in drilling activities. It covers critical areas like equipment integrity, emergency systems, fire protection, PPE compliance, and environmental controls. This tool aids in identifying hazards, verifying standards adherence, minimizing risks, and fostering a safe and compliant work environment in the oil and gas sector.


A. FUEL/WATER TANKS


1. No leaks.

2. Pumps guarded.

3. Signs:

No Smoking Signposted

All tank ID’s

A dangerous goods placard was posted (needed for transportation).


B. BOILER HOUSE

4. No clothing, etc. 

5. Sight glass guarded.

6. Pump guarded.

7. Fire extinguisher.

8. 1 year certification.

9. Boiler 25m from wellhead.

10. Housekeeping.

11. Flammables removed from around the boiler.

12. Manitoba Boiler Registration sticker

13. Blow down line – location, and installation of steam deflector.

14. Fuel/water and steam line leaks.

15. Chemical addition vessel (pot) at boiler properly labeled (WHMIS).


C. GENERATOR BUILDING

16. Generator/motor control center –condition.

17. Receptacles/circuit breakers identified.

18. Properly grounded (2 grd. Rods 3m apart).

19. Wiring guarded or off the ground and properly secured.

20. No clothing/storage.

21. Fans and belts guarded.

22. No fuel/oil leaks.

23. Compressor belts guarded.

24. Fire extinguisher.

25. All lights protected.

26. Housekeeping.

27. Signs

Auto Start signposted.

Hearing Protection Sign posted.

Electrical/High Voltage signs posted.

Water Hose Caution signposted.

Lockout and Procedures.

28. Wiring/electrical fixtures – condition.


D. ACCUMULATOR BUILDING

29. No leaks/spillage.

30. N2 bottles (12500 kPa / 1800 psi).

31. Housekeeping.

32. Storage of compressed gas cylinders secured.

33. Controls identified / accessible.

34. Safety device blind/shear ram controls.

35. Fire extinguisher.

36. Compressor guarded.

37. Signs

Auto Start signs–compressor/Accomm., pump

Dangerous Goods placard.

38. Accumulator reservoir vented outside of building/enclosure.


E. TOOL SHED

39. No leaks/spillage.

40. Housekeeping.

41. Fire extinguisher.

42. Grinder tool rest.

43. Eye protection available.

44. Eye Protection signposted.


F. MUD PUMP AREA

45. Pop valve (direction/pin/cover – flop over or hand tight).

46. Pop/bleed-off lines secured and drained.

47. Hoses safely chained.

48. Fire extinguisher.

49. Housekeeping.

50. Piping, valves & unions meet pressure rating.

51. Pulsation dampers.

52. Eyewash facility.

53. Signs

Lockout procedure posted.

Auto Start signposted.

Hearing Protection signposted.

No Smoking sign posted.

54. Wiring/electrical fixtures – condition.

G. MUD TANK AREA

55. Mud degasser(s) (size and placement).

56. Shale shaker belts guarded (if exposed).

57. Handrails, walkways.

58. Adequate ventilation.

59. Adequate lighting.

60. Personal protective equipment – eye protection, dust masks, rubber gloves/apron.

61. Housekeeping.

62. Tank level indicators operative.

63. Trip tank level indicator tank location.

64. Centrifuge (grounding/elect, handrails, etc)

65. Mud van, stairs, and lighting.

66. Eyewash facility (one must meet MB stds)

67. Signs

Eye Protection signs at hoppers

No Smoking signposted

Applicable WHMIS labeling

68. Wiring / electrical fixtures – condition.

H. SUBSTRUCTURE

69. General condition.

70. Matting condition.

71. All pins are installed, including c/w safety pins.

72. Spreaders in place.

73. Ventilation

74. Illumination

75. Winterization condition

76. Hydraulic control lines – condition fire-guarded hoses (if not labeled, speak to push).

77. Flow nipple split.

78. Scaffolding / ladder(s) condition.

79. Cellar area drained.

80. Wiring / electrical fixtures – condition.

81. Housekeeping (oil leaks, etc.)

I. BOPs

82. BOP secured properly (secured to sub).

83. BOP and rig equipment conform to government regulations.

84. Non-steel hydraulic lines fire sheathed.

85. BOP pressure tests recorded and test procedures satisfactory.

86. Adequate heating.

87. Manual ram locking wheels available. Location

J. DOGHOUSE

88. Potential H2S level posted

89. Adequate exits (min. 2).

90. Housekeeping

91. Fire extinguisher

92. Eye and hearing protection available.

93. Manitoba Standard Eyewash is available

94. First Aid kit stocked and clean (MB #2)

95. Safety belts CSA approved

96. Condition of available hand tools.

97. BOP controls, electrical, manual, air

98. Drilling License posted (super’s shack is adequate).

99. Manitoba emergency phone numbers posted.

100. Signs

Hard Hat signposted.

Hearing Protection signposted.

No Smoking sign posted.

MACP posted.

The blowout procedure is posted and readable.

MSDS’ available

101. Wiring / electrical fixtures – condition.


K. RIG FLOOR

102. Visibility of derrickhand from driller’s station.

103. Mechanical lockouts on draw works.

104. Drawworks are  guarded (no-go zone)

105. Crown saver (check).

106. Spinning chain/wench lines.

107. Headache post.

108. Kelly's cock condition.

109. Kelly hose condition.

110. Kelly hose safety line – both ends.

111. Line spooler/safety line.

112. Backup posts condition.

113. Tongs – condition.

114. Tong line and tong line clamps.

115. Slips – condition.

116. Dog collar – condition.

117. Stabbing valve and handle & X/O subs.

118. All machine guarding in place

119. Mud can condition.

120. All controls are identified.

121. Brake handle hold-down cable/chain.

122. Non-skid material around the rotary.

123. Lighting operational, floor & motor area.

124. Motors

Fans and belts guarded

No fuel/oil leaks

Motor shutoff

Fire extinguisher

Exhaust system

125. Stairs (min. 3 exits) from the rig floor

126. Warning horn working

127. Mobile boom/crane less than 7300 kg

128. Brakes satisfactory

129. Tugger line condition, guards

130. V-door opening safety chained.

131. Wiring / electrical fixtures condition.

132. Block hanging line


L. DERRICK

133. Bumper blocks secured.

134. Fingers straight.

135. Fingers chained/cabled

136. Wind board installed.

137. Ladder condition.

138. Escape line installed—no blockage of the line (i.e. tank or vehicle).

139. Escape buggy installed and accessible.

140. Climbing device/cages. CSA approved

141. Derrick’s hand harness CSA & condition

142. Guy lines/outrigger.

143. No loose tools – equipment cabled on derrick.

144. All safety pins are in place, and secure.

145. Lighting operational and safety cables/chains attached.

146. Condition of tong counterweight assembly.

147. Wiring / electrical fixtures – condition.

148. Logbook (digital info) Current

M. TRAVELLING ASSEMBLY

149. Bails / links.

150. Blocks or top drive

151. Elevators/latches.

152. Weight indicator assembly.

153. Weight indicator safety line.

154. Automatic driller.

155. Drilling line condition (slip/cut program).

156. Deadline anchor condition.

N. PIPE RACK AREA

157. Racks butt firmly to each other and catwalk.

158. The catwalk is in good condition.

159. Stairs – condition.

160. Pipe racks level/ Hydraulic stops in place.

161. The pipe rack ends are properly pinned.

162. The spacer between racks is sturdy and secure.

163. Derrick stands in good condition.

164. Housekeeping.

165. V-door ramp in good condition.

166. Catwalk, tugger, or skate, guarded.

167. Lay down line and block condition.

168. Layers of drill pipe or casing properly chocked.

169. Adequate lighting.

170. Pipe rack matting size and condition (sinking)

O. MANIFOLD HOUSE

171. Valve handles installed.

172. Heated

173. Proper gauges were installed and positioned.

174. Drill pipe pressure gauge installed.

175. Unobstructed view to the rig floor.

176. Housekeeping.

177. Manifold design meets Gov. Requirements.

178. Flare lines properly secured.

179. Lighting operational.

180. Choke/valves open to degasser.

181. Signs

MACP notice posted.

No Smoking sign posted.

182. Choke and degasser lines and manifold prepared for winter operation (if applicable).

183. Number of packs available (min. of 2)


P. BREATHING APPARATUS INSPECTION

184. Location of Air Packs

185. The general condition of apparatus and case.

186. Condition of the face piece.

187. Condition of nose cup.

188. Cylinder pressure.

189. Low-pressure alarm operational.

190. Cleanliness and storage.

191. Positive pressure capability.

192. Number/condition of spare cylinders (min 2)

193. Spare cylinders are properly stored.

194. SCBA cylinders hydrostatic test dates are current.

195. Other

Q. LEASE AREA

196. The lease is clean and neat.

197. Distances

Well to flare pit/flare tank

Well to incinerator

Well to crude oil storage tank

Oil storage tank to pit

Incinerator to flare pit/flare tank

198. Incinerator/garbage bin

199. Adequate ditching and drainage

200. Sump fluids properly contained.

201. Lease properly diked (if applicable)

202. Overhead lines flagged

203. H2S Warning signs, if applicable

R. TICKETS / DOCUMENTS

204. BOP function tests daily, recorded

205. BOP drill with records and signed by Rig Manager and Foreman

206. Motor skills weekly with records.

207. BOP tickets

Rig Manager

Foreman

Drillers

208. First Aid certificate (one per crew)

209. H2S training (all crew members)

210. WHMIS training (all crew members)

211. Slip and cut program recorded.

212. New employee orientation training.


S. SAFETY / GENERAL

213. Rig site trailers – distance from the well center.

214. Condition of electric tools.

215. Personal safety equipment is being used.

216. Toxic gas equipment (detector and tubes)

217. Adequate emergency vehicles are available

218. Accident reporting and recording

219. Rig location signs

220. Stretcher, location.  No.:

221. Condition of handrails and stairs – toe boards.

222. Fire retardant clothing is available

223. Suit casing/walkways

224. All safety hazards addressed at safety meetings (H2S, etc)

225. Other

The above inspection form pertains to all Manitoba legislation, applicable codes, and associated standards related to the upstream oil industry.

In the event items are not corrected within the specified time listed, the infraction may be forwarded to the appropriate enforcement body to ensure compliance is addressed under specific legislation including possible elevated enforcement measures.

INFRACTION / DATE TO BE REPAIRED / INSPECTOR’S COMMENTS

Unless specified otherwise, all issues are to be corrected within one week from the date of the inspection.